Proxmox VE runs well on our servers: NVMe drives give ZFS low latency, ECC memory protects the data ZFS keeps in RAM, and the private VLAN connects the nodes of a cluster. There are two ways to install it.
1. From our image
Choose Proxmox VE 9 when you order or on the Reinstall tab of the client area, with ZFS mirror as the disk layout. The installation places the system on a mirror of the first two NVMe drives with ashift=12 and lz4 compression, installs the SSH keys of your account and configures the public network as the bridge vmbr0. It is the quickest path and gives the same result as the steps below.
2. From the official ISO
Mount the Proxmox VE ISO through the iKVM console, as described in Use the iKVM console and mount an ISO, then:
- At the target disk step, open Options and choose zfs (RAID1) for two drives, or zfs (RAID10) or zfs (RAIDZ-1) for four or more. RAID10 gives virtual machines the best random write performance, while RAIDZ-1 leaves more usable space.
- Keep
ashiftat 12 and compression on, and leavehdsizeempty to use the whole drives. - On the network step, enter the address, gateway and DNS servers listed on the Network tab. The installer creates the bridge
vmbr0on the public interface.
3. Give your virtual machines public addresses
Additional IPv4 addresses and blocks are routed to the main address of your server. Virtual machines therefore reach the internet through the host, which forwards their traffic, instead of appearing on the network with MAC addresses of their own. A minimal routed setup in /etc/network/interfaces:
auto vmbr1
iface vmbr1 inet static
address 198.51.100.1/29
bridge-ports none
bridge-stp off
bridge-fd 0
post-up echo 1 > /proc/sys/net/ipv4/ip_forward
Here 198.51.100.0/29 stands for the block routed to your server. The host takes its first usable address, each virtual machine receives one of the others with 198.51.100.1 as its gateway, and the virtual machines are attached to vmbr1. Apply the change with ifreload -a. IPv6 follows the same model: your /56 is routed to the host, so give each bridge a /64 out of it.
4. Size the ZFS cache
ZFS keeps recently used data in RAM, in what it calls the ARC. The Proxmox installer limits the ARC to 10 percent of the memory, with a ceiling of 16 GiB, which leaves almost everything to your virtual machines. On a host with plenty of memory and a busy pool, a larger cache makes reads faster, for example 64 GiB on a server with 768 GB:
echo "options zfs zfs_arc_max=$((64 * 1024**3))" > /etc/modprobe.d/zfs.conf
update-initramfs -u -k all
The new limit applies after the next restart.
5. Build a cluster
Use the private VLAN for cluster traffic and live migration. Give each node an address on its private port, as shown in Configure the private network on Linux, then create the cluster on the first node with pvecm create and join the others with pvecm add, using the private addresses. Corosync needs low latency, so keep the nodes of one cluster in the same site.