Sustainability. Outside air and reused heat.

Our largest data centers are in places where outside air can do the cooling and where the grid runs on hydroelectric and geothermal power. In Luleå and Helsinki, the heat the servers give off goes into the district heating network instead of being vented.

PUE in Luleå
1.08
renewable in the Nordics
100%
free cooling a year
8,300 h
homes heated
4,200
01PUE by site
  1. LLA1 Luleå 1.08
  2. RKV1 Reykjavík 1.09
  3. OSL1 Oslo 1.12
  4. HEL1 Helsinki 1.13
  5. AMS1 Amsterdam 1.25
  6. FRA1 Frankfurt 1.28
  7. IAD1 Ashburn 1.32
  8. SIN1 Singapore 1.38

Power usage effectiveness (PUE) is the energy a data center draws divided by the energy its IT equipment uses. At 1.08, every kilowatt-hour that reaches the servers costs 0.08 kWh more in cooling and power conversion.

“In Luleå, the chillers stay off for about 8,300 hours a year.”

We measure every site hourly: the energy it draws, the energy that reaches the servers and the heat sent to the district heating network. The figures are published once a year in our energy report.

Where 100 kWh go

LLA1 · LuleåPUE 1.08

92.6 kWh7.4 kWh

Industry average 1.56

64.1 kWh35.9 kWh

Reach the servers Cooling and conversion

A longer life for every server

Servers that leave the main catalog stay in service through the outlet, in the configuration their first customer gave them. When they are finally retired, the drives are wiped to NIST 800-88 and every part goes to certified recyclers.

Outlet
  1. 01

    Sourcing

    Parts are bought new from authorized distributors and carry a full warranty.

  2. 02
    72 h

    Burn-in

    Stress tests run for 72 hours, followed by a final benchmark.

  3. 03

    In use

    The server stays four to six years in the main catalog, monitored 24/7.

  4. 04

    Outlet

    It is rented again in the configuration its last customer chose, wiped, checked like a new server and priced below one.

  5. 05
    NIST 800-88

    Recycling

    Drives are wiped to NIST 800-88 before every part goes to a certified recycler.

Our commitments

01

100% renewable power at every Nordic site

  • LLA1Hydroelectric
  • RKV1Geothermal and hydro
  • OSL1Hydroelectric
  • HEL1Wind power agreement
02

Free cooling wherever the climate allows it

8,300 h

free cooling a year

LLA11.08
RKV11.09
OSL11.12
HEL11.13
04

Second life for hardware through the outlet

51

Ready-to-use servers · limited stock

Outlet

// Deploy today

Configure your server in two minutes.

  • No setup fee
  • Price never raised
  • Cancel any month