Skip to content
ArcticDedicated

// Help center / 7 min read

Configure the private network on Linux

Give the second port of your server an address on your private VLAN with netplan or NetworkManager, raise the MTU to 9000 and test the link.

Last updated October 10, 2026

Every server has a second network port connected to a private VLAN that only your own servers share. It runs at 25 Gbps on most models, at the speed listed on each server page on the others, carries no traffic charges and accepts any addressing plan you choose. With the Arctic Backbone option, the same VLAN reaches your servers in Luleå, Reykjavík, Oslo and Helsinki.

The private port is left unconfigured at installation, because only you know which addresses you want to use on it.

1. Find the interface

bash
ip -br link
# lo               UNKNOWN  00:00:00:00:00:00
# enp65s0f0np0     UP       00:00:5e:00:53:10
# enp65s0f1np1     DOWN     00:00:5e:00:53:11

The public interface is the one that already has an address. The private one is usually the second port of the same card, and its MAC address is listed on the Network tab of the client area, next to the word Private.

2. Choose an addressing plan

Pick a private range that does not overlap with any network you reach over a VPN, for example 10.20.0.0/24 for one site, and give each server its own address in it. When several sites are joined by the Arctic Backbone, one /24 per site keeps routing simple. IPv6 works the same way with a unique local prefix such as fd12:3456:789a::/64.

3. Ubuntu and Debian with netplan

yaml
# /etc/netplan/60-private.yaml
network:
  version: 2
  ethernets:
    enp65s0f1np1:
      addresses: [10.20.0.11/24, "fd12:3456:789a::11/64"]
      mtu: 9000
bash
sudo chmod 600 /etc/netplan/60-private.yaml
sudo netplan try    # rolls the change back by itself if the connection drops

4. Rocky Linux and AlmaLinux with NetworkManager

bash
sudo nmcli connection add type ethernet ifname enp65s0f1np1 con-name private \
  ipv4.method manual ipv4.addresses 10.20.0.11/24 \
  ipv6.method manual ipv6.addresses fd12:3456:789a::11/64 \
  802-3-ethernet.mtu 9000
sudo nmcli connection up private
bash
ping -c 3 10.20.0.12
ping -c 3 -M do -s 8972 10.20.0.12    # 8972 bytes of data plus 28 bytes of headers make 9000

If the second command fails while the first one works, one of the two servers still uses an MTU of 1500. The private VLAN carries frames of up to 9000 bytes, while the public network stays at 1500.

Several VLANs on one port

Additional private VLANs are included, and they arrive tagged on the same port. Each of them gets its own interface, for example with netplan:

yaml
  vlans:
    vlan210:
      id: 210
      link: enp65s0f1np1
      addresses: [10.21.0.11/24]
      mtu: 9000

The number of each VLAN appears on the Network tab.

Ask an engineer